Flow Rate 0.8 M/min -150 M/min
Alternative with :
|
|
SPECIFICATION :
SPECIFICATION (standard) |
X25 (25 Micron) |
X3 (3 Micron) |
X1 (1 Micron) |
XA (0.01 Micron) |
AC (Activate Carbon) |
|||||
Maximum partical size to ISO 8573.1 class |
4 | 3 | 2 | 1 | 1 | |||||
Maximum Oil content to ISO 8573.1 class |
5 | 4 | 2 | 1 | 1 | |||||
Particle removal | 25 micron | 3 micron | 1 micron | 0.01 micron | N/A | |||||
Maximum oil carryover at 20°C(68°F) |
10 mg/m | 10 ppm | 3 mg/m | 3 ppm | 0.1 mg/m | 0.1 ppm | 0.01 mg/m | 0.01 ppm | 0.003 mg/m | 0.003 ppm |
Maximum temperature | 120°C | 248°F | 120°C | 248°F | 120°C | 248°F | 120°C | 248°F | 25°C | 77°F |
Pressure loss-clean & dry | 30mbar | 0.4psi | 0mbar | 0.6psi | 75mbar | 1.1psi | 100mbar | 1.5psi | 75mbar | 1.1psi |
pressure oil saturated | 50mbar | 0.7psi | 75mbar | 1.1psi | 150mbar | 2.2psi | 300mbar | 4.4psi | see notes | |
pressure loss-change element | 400mbar | 6psi | 400mbar | 6psi | 400mbar | 6psi | 400mbar | 6psi | see notes | |
Maximum recommended pressure differential for element change | – | – | 340-400 mbar | 5-10psi | – | – | – | – | – | – |